The use of bispectral index for monitorization of the depth of sedation in procedural sedoanalgesia in the emergency department

dc.authorid0000-0002-9653-8491
dc.authorid0000-0002-3790-9774
dc.authorid0000-0001-8166-659X
dc.contributor.authorGökdağ, Eren
dc.contributor.authorSarı Doğan, Fatma
dc.contributor.authorYılmaz, Sarper
dc.date.accessioned2026-04-17T07:18:55Z
dc.date.available2026-04-17T07:18:55Z
dc.date.issued2026
dc.departmentFakülteler, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümü, Acil Tıp Ana Bilim Dalı
dc.description.abstractAim: To determine the effectiveness of the Bispectral Index (BIS) measurement as an objective criterion for measuring the depth of sedation in the emergency department (ED) by comparing it with the Modified Ramsey Sedation Scale (MRSS), which is a clinical scale for measuring sedation depth. Methods: In this study, the compatibility of BIS values and MRSS values at the moment when the patients reached clinically appropriate sedation depth for intervention in those requiring sedation-analgesia in the ED due to extremity trauma were compared. Results: No statistically significant correlation was found between patients’ initial MRSS scores at the time of intervention and either their initial or minimum BIS values (p>0.05). A moderate negative correlation (r=-0.432, p=0.022) was observed between the MRSS values and the minimum BIS readings. No statistically significant difference was observed in minimum BIS values based on the sedative agent administered (p>0.05). Conclusion: In this study, a moderate correlation was found between the lowest BIS values and the MRSS scores corresponding to those BIS values. Although further comprehensive and detailed studies are necessary to establish the limitations and optimal use of BIS monitoring during procedural sedation-analgesia in the ED—especially considering both existing literature and the limitations of this study—BIS appears to be a promising alternative to clinical sedation scales for monitoring sedation depth.
dc.identifier.citationGökdağ, E., Sarı Doğan, F., & Yılmaz, S. (2026). The use of bispectral index for monitorization of the depth of sedation in procedural sedoanalgesia in the emergency department. Annals of Clinical and Analytical Medicine, 17, pp. 119-123. https://doi.org/10.4328/ACAM.22682
dc.identifier.doi10.4328/ACAM.22682
dc.identifier.endpage123
dc.identifier.issn2667-663X
dc.identifier.startpage119
dc.identifier.urihttps://doi.org/10.4328/ACAM.22682
dc.identifier.urihttps://hdl.handle.net/20.500.13055/1418
dc.identifier.volume17
dc.identifier.wosWOS:001721396700005
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynak.otherESCI - Emerging Sources Citation Index
dc.institutionauthorGökdağ, Eren
dc.institutionauthorid0000-0002-9653-8491
dc.language.isoen
dc.publisherBayrakol Medical Publisher
dc.relation.ispartofAnnals of Clinical and Analytical Medicine
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectSedation
dc.subjectModified Ramsey Sedation Scale
dc.subjectBispectral Index
dc.subjectEmergency Department
dc.subjectSedation Depth Measurement
dc.titleThe use of bispectral index for monitorization of the depth of sedation in procedural sedoanalgesia in the emergency department
dc.typeArticle
dspace.entity.typePublication

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Tam Metin / Full Text.pdf
Boyut:
172.26 KB
Biçim:
Adobe Portable Document Format
Lisans paketi
Listeleniyor 1 - 1 / 1
Kapalı Erişim
İsim:
license.txt
Boyut:
1.17 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: