Evaluation of shaping performance and surface changes of two different minimally invasive shaping file systems used in resin blocks

Yükleniyor...
Küçük Resim

Tarih

2023

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

MediHealth Academy Yayıncılık

Erişim Hakkı

info:eu-repo/semantics/openAccess

Araştırma projeleri

Organizasyon Birimleri

Dergi sayısı

Özet

Aims: This study aimed to compare the shaping ability of T-endo MIS and TruNatomy (TRN) file systems in J-shaped resin root canals and to investigate the deformation of the files after two acrylic block preparation and two sterilization cycles. Methods: Forty acrylic blocks were numbered, then four file groups (n=10) were established: T-endo MIS glider (15.04) + T-endo MIS Finisher (25.04) (first and second usage) and TRN Glider (17.02) + TRN Prime (26.04) (first and second usage). Preoperative and postoperative images after the root canal preparation of simulated acrylic blocks were taken for each sample, and superimposed. The amount of resin removed from both the inner and outer walls of the canal to the level of 3, 5, and 7 mm from the apical point was measured, and the amount of transportation was calculated. Additionally, the deformation of the files was examined under a scanning electron microscope before and after usage and sterilization process. Results: Tip deformation of TRN files increased with the number of uses (p=0.007). With the second use, the surface deformation of the MIS files increased (p=0.015). There was no difference in cutting-edge deformation in either file type according to the number of uses (p>0.05). There was no difference in transportation values between the MIS and TRN file systems at any level (p>0.05). The file systems did not show a significant difference in the amount of transportation between first and second use (p>0.05). Conclusion: When TRN (26.04) and MIS (25.04) NiTi rotary files were used twice on acrylic blocks, the amount of deformation did not differ. Both file types were similar in terms of transportation values.

Açıklama

Anahtar Kelimeler

Acrylic Block, Canal Transportation, File Deformation, Minimally Invasive Shaping

Kaynak

Journal of Health Sciences and Medicine

WoS Q Değeri

Scopus Q Değeri

Cilt

6

Sayı

4

Künye

Yeniçeri Özata, M., Falakaloğlu, S., & Eskibağlar, M. (2023). Evaluation of shaping performance and surface changes of two different minimally invasive shaping file systems used in resin blocks. Journal of Health Sciences and Medicine, 6(4), pp. 826-832. https://doi.org/10.32322/jhsm.1315227