A liquid chromatographic analysis of deferasirox in human breast milk with fluorimetric detection
dc.contributor.author | Önal, Cem | |
dc.contributor.author | Tekkeli Kepekçi, Şerife Evrim | |
dc.contributor.author | Sağıroğlu, Ali Asram | |
dc.date.accessioned | 2021-12-23T12:24:27Z | |
dc.date.available | 2021-12-23T12:24:27Z | |
dc.date.issued | 2020 | en_US |
dc.department | Fakülteler, Eczacılık Fakültesi, Eczacılık Meslek Bilimleri Bölümü, Analitik Kimya Ana Bilim Dalı | en_US |
dc.description.abstract | To determine deferasirox in human breast milk a novel, sensitive high-performance liquid chromatographic method with fluorescence detection has been developed. Precolumn derivatization process is applied to achieve fluorescent analyte using 4-bromomethyl-7-methoxy coumarin (BrMmC) as a reagent and dibenzo-18-crown-6-ether as catalyst. The method depends on reverse phase chromatography. C(18)column has been used with 150 x 4.6 mm, 5 mu m particle size and the mobile phase consisting of acetonitrile:phosphate buffer (20 mM, pH 3) (70:30,v/v) with a flow rate of 1.0 mL/min. Fluorescence detection at 390 nm is provided with an excitation at 320 nm The linear range is 0.01-1.0 mu g/mL. The mean recovery has been calculated as 100.7% with a relative standard deviation (RSD) value less than 2%. The developed method was successfully applied for the determination of deferasirox in human breast milk samples. | en_US |
dc.identifier.citation | Önal, C., Tekkeli, S. E. K., & Sağıroglu, A. A. (2020). A Liquid Chromatographic Analysis of Deferasirox in Human Breast Milk with Fluorimetric Detection. Chromatographia. 83(11), pp. 1329-1333. https://doi.org/10.1007/s10337-020-03953-5 | en_US |
dc.identifier.doi | 10.1007/s10337-020-03953-5 | en_US |
dc.identifier.endpage | 1333 | en_US |
dc.identifier.issue | 11 | en_US |
dc.identifier.scopus | 2-s2.0-85090498154 | en_US |
dc.identifier.scopusquality | Q2 | en_US |
dc.identifier.startpage | 1329 | en_US |
dc.identifier.uri | https://doi.org/10.1007/s10337-020-03953-5 | |
dc.identifier.uri | https://hdl.handle.net/20.500.13055/110 | |
dc.identifier.volume | 83 | en_US |
dc.identifier.wos | WOS:000568232100001 | en_US |
dc.identifier.wosquality | Q3 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.indekslendigikaynak.other | SCI-E - Science Citation Index Expanded | en_US |
dc.institutionauthor | Önal, Cem | |
dc.language.iso | en | en_US |
dc.publisher | Springer | en_US |
dc.relation.ispartof | Chromatographia | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Defarasirox | en_US |
dc.subject | Liquid Chromatography | en_US |
dc.subject | Fluorescence Detection | en_US |
dc.subject | Human Breast Milk | en_US |
dc.title | A liquid chromatographic analysis of deferasirox in human breast milk with fluorimetric detection | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication |
Dosyalar
Orijinal paket
1 - 1 / 1
Kapalı Erişim
- İsim:
- Onal-2020-A-liquid-chromatographic-analysis-o.pdf
- Boyut:
- 610.78 KB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Tam Metin / Full Text
Lisans paketi
1 - 1 / 1
Kapalı Erişim
- İsim:
- license.txt
- Boyut:
- 1.44 KB
- Biçim:
- Item-specific license agreed upon to submission
- Açıklama: