Effect of power arm length and attachment configuration on maxillary molar mesialization with clear aligners: A finite element analysis

dc.authorid0009-0007-9970-4292
dc.authorid0009-0004-6316-6072
dc.contributor.authorÇavuşoğlu, Ahmet
dc.contributor.authorErdem, Buket
dc.date.accessioned2026-11-09T11:18:44Z
dc.date.available2026-11-09T11:18:44Z
dc.date.issued2026
dc.departmentFakülteler, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümü, Ortodonti Ana Bilim Dalı
dc.description.abstractBackground Maxillary molar mesialization with clear aligners is challenging because achieving controlled root movement without excessive mesial tipping remains difficult. Although power arms can modify the force system, the combined effects of power-arm length and attachment configuration on molar displacement and tipping remain insufficiently characterized. This study evaluated the effects of 6-, 8-, and 10-mm power arms combined with two attachment configurations during maxillary first molar mesialization using three-dimensional finite element analysis. Methods The attachment configurations were selected to represent two clinically distinct approaches to integrating a vertical attachment with a power arm: a palatal vertical attachment combined with a buccal cut-out and a buccal vertical attachment with direct power-arm integration. Six three-dimensional finite element models were constructed by combining three power arm lengths (6, 8, and 10 mm) with two attachment configurations: a palatal vertical attachment with a buccal cut-out, and a buccal vertical attachment without a cut-out. A mesial force of 200 g was applied from a temporary anchorage device (TAD) to the power arm. Displacements were measured along the X (bucco–palatal), Y (mesio–distal), and Z (occluso–gingival) axes. Peak von Mises stress values in the periodontal ligament and aligner deformation were evaluated. Results In all models, maxillary first molar displacement occurred predominantly in the mesial and gingival directions. Mesial crown displacement ranged from 0.068 to 0.074 mm, while distal displacement at the root apex ranged from 0.011 to 0.012 mm. Mesial tipping angles ranged from 0.155° to 0.170°, with higher tipping observed in models with shorter power arms. Increasing power arm length was consistently associated with reduced mesial tipping and lower periodontal ligament stress, but with reduced mesial crown displacement. Shorter power arms generated higher periodontal ligament stress, whereas longer power arms were associated with greater aligner deformation. Conclusions Power arm length and attachment configuration were associated with differences in initial tooth displacement patterns, periodontal ligament stress distribution, and aligner deformation during maxillary first molar mesialization with clear aligners. Longer power arms were associated with reduced mesial tipping and lower periodontal ligament stress, but also with reduced mesial crown displacement. The buccal vertical attachment configuration consistently produced lower mesial rotation than the palatal vertical attachment with buccal cut-out configuration at each corresponding power-arm length; this difference should be interpreted as a configuration dependent finding within the initial biomechanical response.
dc.identifier.citationÇavuşoğlu, A., & Erdem, B. (2026). Effect of power arm length and attachment configuration on maxillary molar mesialization with clear aligners: A finite element analysis. BMC Oral Health, 26(1), pp. 1-13. https://doi.org/10.1186/s12903-026-09893-0
dc.identifier.doi10.1186/s12903-026-09893-0
dc.identifier.endpage13
dc.identifier.issn1472-6831
dc.identifier.issue1
dc.identifier.pmidPMID: 42806319
dc.identifier.scopus2-s2.0-105051824016
dc.identifier.scopusqualityQ1
dc.identifier.startpage1
dc.identifier.urihttps://doi.org/10.1186/s12903-026-09893-0
dc.identifier.urihttps://hdl.handle.net/20.500.13055/1702
dc.identifier.volume26
dc.identifier.wosWOS:001888726300001
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.indekslendigikaynak.otherSCI-E - Science Citation Index Expanded
dc.institutionauthorÇavuşoğlu, Ahmet
dc.institutionauthorErdem, Buket
dc.institutionauthorid0009-0007-9970-4292
dc.institutionauthorid0009-0004-6316-6072
dc.language.isoen
dc.publisherBioMed Central
dc.relation.ispartofBMC Oral Health
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectFinite Element Analysis
dc.subjectClear Aligners
dc.subjectMolar Mesialization
dc.subjectPower Arm
dc.titleEffect of power arm length and attachment configuration on maxillary molar mesialization with clear aligners: A finite element analysis
dc.typeArticle
dspace.entity.typePublication

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Kapalı Erişim
İsim:
Tam Metin / Full Text.pdf
Boyut:
3.04 MB
Biçim:
Adobe Portable Document Format
Lisans paketi
Listeleniyor 1 - 1 / 1
Kapalı Erişim
İsim:
license.txt
Boyut:
1.17 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: