Impression precision after hydrogen peroxide sterilization of scanner sleeves

dc.authorid0000-0002-7961-0535
dc.authorid0000-0003-0331-8463
dc.authorid0000-0001-8192-2784
dc.contributor.authorYılmaz, Berza
dc.contributor.authorArslan, Meriç
dc.contributor.authorKayasaroğlu, Damla Nur
dc.contributor.authorArslan, Elif Dilara
dc.contributor.authorSunal Aktürk, Ezgi
dc.date.accessioned2026-04-24T17:01:55Z
dc.date.available2026-04-24T17:01:55Z
dc.date.issued2026
dc.departmentFakülteler, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümü, Ortodonti Ana Bilim Dalı
dc.description.abstractIntroduction The iTero Element (Align Technologies, San Jose, CA, USA) is a widely used intraoral scanning device, and its protective sleeves for the scanning head are provided for single use. This condition puts the clinical management budget under financial strain and creates a disadvantage for managing environmental waste. The objective of our research was to assess how repeated sterilization of disposable scan head covers with hydrogen peroxide affected the precision of digital impressions. Methods Intraoral scans were carried out using the iTero Element 5D scanner on 26 patients. Hydrogen peroxide was used to sterilize the sleeves for 45min at 45 °C. The sterilization procedure was repeated between the second, third, and fourth intraoral scans. Each tooth was given a score based on the color change between the first and fourth scans, which were superimposed using the iTero TimeLapse technology. The OrthoCAD® software (Align Technologies) was also used to measure the intercanine, interpremolar, and intermolar distances, as well as the mesiodistal dimensions of all the teeth between the first molars. Results No statistically significant difference was found between the mesiodistal dimensions of the teeth and the interca nine, interpremolar, and intermolar distances between the 1st and 4th scans. There was no correlation between the mean differences of the mesiodistal dimensions of the teeth obtained with the 1st and 4th scans and TimeLapse scores. Conclusion After sterilization with hydrogen peroxide, the repeatability of digital measurements of the protective sleeves of the intraoral scanner was not adversely affected, and their clinical performance was maintained.
dc.identifier.citationYılmaz, B., Arslan, M., Kayasaroğlu, D. N., Arslan, E. D., & Sunal Aktürk, E. (2026). Impression precision after hydrogen peroxide sterilization of scanner sleeves. Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie, https://doi.org/10.1007/s00056-026-00657-7
dc.identifier.doi10.1007/s00056-026-00657-7
dc.identifier.issn1434-5293
dc.identifier.pmidPMID: 42009857
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://doi.org/10.1007/s00056-026-00657-7
dc.identifier.urihttps://hdl.handle.net/20.500.13055/1447
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.indekslendigikaynak.otherSCI-E - Science Citation Index Expanded
dc.institutionauthorArslan, Meriç
dc.language.isoen
dc.publisherSpringer Nature Link
dc.relation.ispartofJournal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectEquipment Reuse/Sustainability
dc.subjectEquipment Safety
dc.subjectAccuracy
dc.subjectClinical Performance
dc.subjectDigital Measurements
dc.titleImpression precision after hydrogen peroxide sterilization of scanner sleeves
dc.typeArticle
dspace.entity.typePublication

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Kapalı Erişim
İsim:
Tam Metin / Full Text.pdf
Boyut:
911.08 KB
Biçim:
Adobe Portable Document Format
Lisans paketi
Listeleniyor 1 - 1 / 1
Kapalı Erişim
İsim:
license.txt
Boyut:
1.17 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: