Fluorescence HPLC analysis of teriflunomide in human plasma following derivatization with 4-chloro-7-nitrobenzofurazan: Method development and application to a prototype pharmacokinetic evaluation

Yükleniyor...
Küçük Resim

Tarih

2026

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

MDPI Publishing

Erişim Hakkı

info:eu-repo/semantics/openAccess

Araştırma projeleri

Organizasyon Birimleri

Dergi sayısı

Özet

Background/Objectives: Teriflunomide is an active metabolite of leflunomide and acts as a selective and reversible inhibitor of dihydroorotate dehydrogenase, a key enzyme in de novo pyrimidine biosynthesis. It exhibits immunomodulatory activity by reducing the proliferation of activated T and B lymphocytes and is widely used in the treatment of rheumatoid arthritis and relapsing multiple sclerosis. This study aimed to develop a rapid, accurate, and simple high-performance liquid chromatography (HPLC) method with fluorometric detection for quantifying teriflunomide in human plasma. Methods: Plasma samples were prepared by liquid–liquid extraction followed by pre-column derivatization with NBD-Cl. Teriflunomide was derivatized with 4-chloro-7-nitrobenzofurazan (NBD-Cl) and separated using a reversed-phase C18 column (5 µm, 4.6 × 150 mm) at 30 ◦C with isocratic elution. The mobile phase consisted of acetonitrile and 0.1% orthophosphoric acid (80:20, v/v) at a flow rate of 1.1 mL/min. Fluorescence detection was performed at λex = 465 nm and λem = 535nm. ThemethodmeetsEuropean Medicines Agency (EMA) guide lines for bioanalytical validation and was successfully applied to pharmacokinetic studies, including AUC0–t, AUC0–∞, Cmax, Tmax, and t½. Results: Teriflunomide showed a retention time of 2.55 ± 0.01 min. The method exhibited linearity in the range of 0.01–30 ng/mL (r2 = 0.9998), with a limit of detection and quantification of 0.003 and 0.01 ng/mL, respec tively. The relative standard deviation was 3.27%. Conclusions: This work introduces a novel, cost-effective, and highly sensitive HPLC with fluorescence detection (HPLC-FL) method for the determination of teriflunomide in human plasma, providing an efficient alternative to LC-MS/MS for routine pharmacokinetic and bioequivalence studies.

Açıklama

Anahtar Kelimeler

Teriflunomide, HPLC-FL, Pre-Column Derivatization, Validation, Pharmacokinetics

Kaynak

Pharmaceuticals

WoS Q Değeri

Q1

Scopus Q Değeri

Q1

Cilt

19

Sayı

7

Künye

Çayci, M., Ceylan, B., & Önal, C. (2026). Fluorescence HPLC analysis of teriflunomide in human plasma following derivatization with 4-chloro-7-nitrobenzofurazan: Method development and application to a prototype pharmacokinetic evaluation. Pharmaceuticals, 19(7), pp. 1-12. https://doi.org/10.3390/ph19070987