Evaluation of the validity of mental foramen USG measurements by comparison with CBCT and determination of blood flow
dc.authorid | 0000-0001-8970-7579 | en_US |
dc.authorscopusid | 57204475611 | en_US |
dc.authorwosid | ABB-4899-2020 | en_US |
dc.contributor.author | Artaş, Aslıhan | |
dc.contributor.author | Yalçın, Eda Didem | |
dc.date.accessioned | 2023-05-22T13:23:09Z | |
dc.date.available | 2023-05-22T13:23:09Z | |
dc.date.issued | 2023 | en_US |
dc.department | Fakülteler, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümü, Ağız, Diş ve Çene Radyolojisi Ana Bilim Dalı | en_US |
dc.description.abstract | Objectives: To examine mental foramen (MF) morphology and morphometry in comparison with ultrasonography (USG) and cone-beam computed tomography (CBCT), and to determine the relationship between mental artery blood flow parameters and age, gender, dental status, alveolar crest height, mandibular cortical index (MCI) with USG. Methods: A total of 120 MF and mental arteries of 60 patients (21 males and 39 females), including 20 patients in each group, aged 18-39, 40-59, and 60 years and above, were evaluated. The horizontal and vertical diameter of the MF and the distance between it and the alveolar crest were evaluated with USG and CBCT. In addition, mental artery blood flow parameters were examined by USG. Results: When the horizontal diameter values of MF were compared in USG and CBCT measurements; the diameter was significantly lower in the measurements obtained by USG (p < 0.05). It was observed that there were no mental arteries whose blood flow could not be recorded, 31 (25.8%) had strong blood flow and 89 (74.2%) had weak blood flow. No significant correlation was observed between gender and blood flow parameters (p > 0.05). Conclusions: Considering that CBCT images are used as gold standard in our study, it may be said that USG is not as reliable as CBCT in evaluating the MF dimensions in the maxillofacial region. Nevertheless, USG is a suitable technique for determining the visualizing and blood flow of the MF. | en_US |
dc.identifier.citation | Artaş, A., & Yalçın, E. D. (2023). Evaluation of the validity of mental foramen USG measurements by comparison with CBCT and determination of blood flow. Oral Radiology, 39(4), pp. 699-707. https://doi.org/10.1007/s11282-023-00687-6 | en_US |
dc.identifier.doi | 10.1007/s11282-023-00687-6 | en_US |
dc.identifier.endpage | 707 | en_US |
dc.identifier.issn | 1613-9674 | |
dc.identifier.issn | 0911-6028 | |
dc.identifier.issue | 4 | en_US |
dc.identifier.pmid | PMID: 37210690 | en_US |
dc.identifier.scopus | 2-s2.0-85160257343 | en_US |
dc.identifier.scopusquality | Q2 | en_US |
dc.identifier.startpage | 699 | en_US |
dc.identifier.uri | https://doi.org/10.1007/s11282-023-00687-6 | |
dc.identifier.uri | https://hdl.handle.net/20.500.13055/466 | |
dc.identifier.volume | 39 | en_US |
dc.identifier.wos | WOS:000991634000001 | en_US |
dc.identifier.wosquality | Q4 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.indekslendigikaynak | PubMed | en_US |
dc.indekslendigikaynak.other | SCI-E - Science Citation Index Expanded | en_US |
dc.language.iso | en | en_US |
dc.publisher | Springer | en_US |
dc.relation.ispartof | Oral Radiology | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Cone-Beam Computed Tomography | en_US |
dc.subject | Mental Artery | en_US |
dc.subject | Mental Foramen | en_US |
dc.subject | Ultrasonography | en_US |
dc.title | Evaluation of the validity of mental foramen USG measurements by comparison with CBCT and determination of blood flow | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication |
Dosyalar
Orijinal paket
1 - 1 / 1
Kapalı Erişim
- İsim:
- Evaluation of the validity of mental foramen USG measurements by comparison with CBCT and determination of blood flow.pdf
- Boyut:
- 761.63 KB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Tam Metin / Full Text
Lisans paketi
1 - 1 / 1
Kapalı Erişim
- İsim:
- license.txt
- Boyut:
- 1.44 KB
- Biçim:
- Item-specific license agreed upon to submission
- Açıklama: