Evaluation of the validity of mental foramen USG measurements by comparison with CBCT and determination of blood flow

dc.authorid0000-0001-8970-7579en_US
dc.authorscopusid57204475611en_US
dc.authorwosidABB-4899-2020en_US
dc.contributor.authorArtaş, Aslıhan
dc.contributor.authorYalçın, Eda Didem
dc.date.accessioned2023-05-22T13:23:09Z
dc.date.available2023-05-22T13:23:09Z
dc.date.issued2023en_US
dc.departmentFakülteler, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümü, Ağız, Diş ve Çene Radyolojisi Ana Bilim Dalıen_US
dc.description.abstractObjectives: To examine mental foramen (MF) morphology and morphometry in comparison with ultrasonography (USG) and cone-beam computed tomography (CBCT), and to determine the relationship between mental artery blood flow parameters and age, gender, dental status, alveolar crest height, mandibular cortical index (MCI) with USG. Methods: A total of 120 MF and mental arteries of 60 patients (21 males and 39 females), including 20 patients in each group, aged 18-39, 40-59, and 60 years and above, were evaluated. The horizontal and vertical diameter of the MF and the distance between it and the alveolar crest were evaluated with USG and CBCT. In addition, mental artery blood flow parameters were examined by USG. Results: When the horizontal diameter values of MF were compared in USG and CBCT measurements; the diameter was significantly lower in the measurements obtained by USG (p < 0.05). It was observed that there were no mental arteries whose blood flow could not be recorded, 31 (25.8%) had strong blood flow and 89 (74.2%) had weak blood flow. No significant correlation was observed between gender and blood flow parameters (p > 0.05). Conclusions: Considering that CBCT images are used as gold standard in our study, it may be said that USG is not as reliable as CBCT in evaluating the MF dimensions in the maxillofacial region. Nevertheless, USG is a suitable technique for determining the visualizing and blood flow of the MF.en_US
dc.identifier.citationArtaş, A., & Yalçın, E. D. (2023). Evaluation of the validity of mental foramen USG measurements by comparison with CBCT and determination of blood flow. Oral Radiology, 39(4), pp. 699-707. https://doi.org/10.1007/s11282-023-00687-6en_US
dc.identifier.doi10.1007/s11282-023-00687-6en_US
dc.identifier.endpage707en_US
dc.identifier.issn1613-9674
dc.identifier.issn0911-6028
dc.identifier.issue4en_US
dc.identifier.pmidPMID: 37210690en_US
dc.identifier.scopus2-s2.0-85160257343en_US
dc.identifier.scopusqualityQ2en_US
dc.identifier.startpage699en_US
dc.identifier.urihttps://doi.org/10.1007/s11282-023-00687-6
dc.identifier.urihttps://hdl.handle.net/20.500.13055/466
dc.identifier.volume39en_US
dc.identifier.wosWOS:000991634000001en_US
dc.identifier.wosqualityQ4en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.indekslendigikaynak.otherSCI-E - Science Citation Index Expandeden_US
dc.language.isoenen_US
dc.publisherSpringeren_US
dc.relation.ispartofOral Radiologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCone-Beam Computed Tomographyen_US
dc.subjectMental Arteryen_US
dc.subjectMental Foramenen_US
dc.subjectUltrasonographyen_US
dc.titleEvaluation of the validity of mental foramen USG measurements by comparison with CBCT and determination of blood flowen_US
dc.typeArticleen_US
dspace.entity.typePublication

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Kapalı Erişim
İsim:
Evaluation of the validity of mental foramen USG measurements by comparison with CBCT and determination of blood flow.pdf
Boyut:
761.63 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text
Lisans paketi
Listeleniyor 1 - 1 / 1
Kapalı Erişim
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: