Comparison of reference intervals derived by direct and indirect methods based on compatible datasets obtained in Turkey

Yükleniyor...
Küçük Resim

Tarih

2021

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Elsevier

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Araştırma projeleri

Organizasyon Birimleri

Dergi sayısı

Özet

Background: Indirect derivation of reference intervals (RIs) from the laboratory information system (LIS) has been recently pursued. We aimed at evaluating the accuracy of indirectly predicted RIs compared to the RIs established directly from healthy subjects in the nationwide RI study in Turkey, targeting 25 major chemistry analytes. Methods: LIS data were retrieved from the laboratory that performed measurements for the direct study. They were cleaned by limiting to outpatients with age 18-65 years, and by allowing only one record per year per patient. Evaluated were four indirect methods of univariate approach: Hoffmann, Bhattacharya, Arzideh, and Wosniok methods. Power transformation of the LIS dataset was performed either using the power (lambda) reported by the IFCC global RI study (the first two methods) or using a lambda predicted (the last two). Results: Compared to the direct study dataset, the LIS dataset showed a variable degree of alterations in peak location and shape. Consequently, lower-side peak-shifts observed in sodium, albumin, etc. led to lowered RI limits, whereas higher-side peak-shift observed in triglyceride, low-density lipoprotein cholesterol, etc. led to raised RI limits. Overall, 72% (62-81) of the RI limits predicted by indirect methods showed significant biases from direct RIs. However, the biases observed in total cholesterol, lactic dehydrogenase, etc. were attributed to a higher-side age-bias in LIS dataset. After excluding them, the overall proportion of biased RIs was reduced to 47% (38-54). Conclusion: To reduce prediction biases that remained after age adjustment, it is necessary to apply more rigorous data-cleaning before applying indirect methods.

Açıklama

Anahtar Kelimeler

Laboratory Information System (LIS), Power Transformation, Parametric Method, Hoffmann Method, Bhattacharya Method, Arzideh Method, Wosniok Method, Latent Abnormal Values Exclusion (Lave)

Kaynak

Clinica Chimica Acta

WoS Q Değeri

Q1

Scopus Q Değeri

Q1

Cilt

520

Sayı

Künye

Özarda, Y., Ichihara, K., Jones, G., Streichert, T., & Ahmadian, R. (2021). Comparison of reference intervals derived by direct and indirect methods based on compatible datasets obtained in Turkey. Clinica Chimica Acta, 520, pp. 186-195. https://doi.org/10.1016/j.cca.2021.05.030