Evaluation of shaping ability of different glide path instruments: A micro-computed tomography study
dc.authorid | 0000-0001-5230-969X | en_US |
dc.authorscopusid | 57200111076 | en_US |
dc.authorwosid | FZG-2029-2022 | en_US |
dc.contributor.author | Yeniçeri Özata, Merve | |
dc.contributor.author | Falakaloğlu, Seda | |
dc.contributor.author | Keleş, Ali | |
dc.contributor.author | Adıgüzel, Özkan | |
dc.contributor.author | Gündoğar, Mustafa | |
dc.date.accessioned | 2023-11-02T07:35:54Z | |
dc.date.available | 2023-11-02T07:35:54Z | |
dc.date.issued | 2023 | en_US |
dc.department | Fakülteler, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümü, Endodonti Ana Bilim Dalı | en_US |
dc.description.abstract | Background: This study aimed to compare the shaping ability of different instruments, TruNatomy Glider (TRN-G), WaveOne Gold Glider (WOG-G), and ProGlider (Pro-G) using micro-computed tomography (micro-CT). Methods: The mesial canals of 27 mandibular molars with two separate mesial canals and moderate curvature were included in this study [n = 27 mesiobuccal (MB) and mesiolingual (ML) root canal]. According to the manufacturer's instructions, the glide path was created with TRN-G, WOG-G, and Pro-G glide path instruments (n = 9 MB and ML root canal in each group). Micro-CT scanning was performed before and after preparation. Mesiodistal (MD) and buccolingual (BL) transportation and the centering ratio were measured at three levels within the canal (3, 5 and 7 mm). A three-way robust ANOVA was used to compare the parameters. Results: TRN-G showed significantly greater transportation in the MD direction than the other instruments throughout the root canal (overall root canal) (p < 0.05). The best centering ability in the BL direction was shown by the WOG-G, regardless of level within the canal and canal distinction (MB vs. ML) (p < 0.05). There was no significant difference between groups according to the level within the canal and canal parameters (p > 0.05). Whether the root canal was MB or ML did not affect centering or transportation (p > 0.05). Conclusions: Glide path instruments can be used to shape moderately curved canals with minimal apical transportation and better centering ability. All three tested glide path files can used safely before the shaping file. | en_US |
dc.description.sponsorship | Dicle University Scientific Research Projects Coordinatorship -- DIS.20.024 | en_US |
dc.identifier.citation | Yeniçeri Özata, M., Falakaloğlu, S., Keleş, A., Adıgüzel, Ö., & Gündoğar, M. (2023). Evaluation of shaping ability of different glide path instruments: a micro-computed tomography study. BMC Oral Health, 23(1), pp. 1-9. https://doi.org/10.1186/s12903-023-03529-3 | en_US |
dc.identifier.doi | 10.1186/s12903-023-03529-3 | en_US |
dc.identifier.endpage | 9 | en_US |
dc.identifier.issn | 1472-6831 | |
dc.identifier.issue | 1 | en_US |
dc.identifier.pmid | PMID: 37875946 | en_US |
dc.identifier.scopus | 2-s2.0-85174806076 | en_US |
dc.identifier.scopusquality | Q2 | en_US |
dc.identifier.startpage | 1 | en_US |
dc.identifier.uri | https://doi.org/10.1186/s12903-023-03529-3 | |
dc.identifier.uri | https://hdl.handle.net/20.500.13055/571 | |
dc.identifier.volume | 23 | en_US |
dc.identifier.wos | WOS:001089108600001 | en_US |
dc.identifier.wosquality | Q2 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.indekslendigikaynak | PubMed | en_US |
dc.indekslendigikaynak.other | SCI-E - Science Citation Index Expanded | en_US |
dc.institutionauthor | Falakaloğlu, Seda | |
dc.language.iso | en | en_US |
dc.publisher | BMC | en_US |
dc.relation.ispartof | BMC Oral Health | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Glide Path | en_US |
dc.subject | Proglider | en_US |
dc.subject | Shaping Ability | en_US |
dc.subject | Trunatomy Glider | en_US |
dc.subject | Waveone Gold Glider | en_US |
dc.title | Evaluation of shaping ability of different glide path instruments: A micro-computed tomography study | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication |
Dosyalar
Orijinal paket
1 - 1 / 1
Yükleniyor...
- İsim:
- Evaluation of shaping ability of different glide path instruments a micro-computed tomography study.pdf
- Boyut:
- 1017.96 KB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Tam Metin / Full Text
Lisans paketi
1 - 1 / 1
Kapalı Erişim
- İsim:
- license.txt
- Boyut:
- 1.44 KB
- Biçim:
- Item-specific license agreed upon to submission
- Açıklama: