CBCT artifact evaluation in a single device: Insights and limitations
dc.authorid | 0000-0001-8970-7579 | en_US |
dc.authorscopusid | 57204475611 | en_US |
dc.authorwosid | ABB-4899-2020 | en_US |
dc.contributor.author | Yalçın, Eda Didem | |
dc.contributor.author | Aslan Öztürk, Elif Meltem | |
dc.date.accessioned | 2024-07-04T15:12:28Z | |
dc.date.available | 2024-07-04T15:12:28Z | |
dc.date.issued | 2024 | en_US |
dc.department | Fakülteler, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümü, Ağız, Diş ve Çene Radyolojisi Ana Bilim Dalı | en_US |
dc.description.abstract | Objective: To classify the types of artifacts in cone-beam computed tomography (CBCT) and to evaluate them according to age and gender. Methods: CBCT images of 1500 patients (766 males and 734 females) aged 5-92 (mean age: 40.89 ± 18.82 years) were retrospectively evaluated and the patients were categorized into 4 age groups: under 20 years old, 20-39 ages, 40-59 and over 60 years old. The types of artifacts encountered in CBCT images were classified. The relationship between the artifact types with age and gender were investigated. Chi-square test was applied to analyze the relationships between variables and distribution of parameters. Results: Of the cases, 284 (18.9%) were under the age of 20, 389 (25.9%) were between the ages of 20-39, 554 (36.9%) were between the ages of 40-59 and 273 (18.2%) were over the age of 60. Moire artifact was observed at the highest rate (100%), while motion artifact was determined at the lowest rate (19.5%), and no ring artifact was detected in the analyzed images. Metallic artifact, metallic artifact removal, streak artifact and presence of dark bands were found to be statistically significant in females (p = .002, p = .001, p = .002 and p = .002, respectively). There was no statistically significant correlation between cupping artifact, metallic artifact, metallic artifact removal, streak artifact, dark band and noise, and stitched artifact (p > .05). Conclusion: Both device and patient-based artifacts in CBCT images should be known, as well as the ways to prevent them. | en_US |
dc.identifier.citation | Yalçın, E. D., & Aslan Öztürk, E. M. (2024). CBCT artifact evaluation in a single device: Insights and limitations. Clinical and Experimental Health Sciences, 14(2), pp. 349-356. https://doi.org/10.33808/clinexphealthsci.1291106 | en_US |
dc.identifier.doi | 10.33808/clinexphealthsci.1291106 | en_US |
dc.identifier.endpage | 356 | en_US |
dc.identifier.issue | 2 | en_US |
dc.identifier.startpage | 349 | en_US |
dc.identifier.uri | https://doi.org/10.33808/clinexphealthsci.1291106 | |
dc.identifier.uri | https://hdl.handle.net/20.500.13055/730 | |
dc.identifier.volume | 14 | en_US |
dc.identifier.wos | WOS:001266664000001 | en_US |
dc.identifier.wosquality | Q4 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | TR-Dizin | en_US |
dc.indekslendigikaynak.other | ESCI - Emerging Sources Citation Index | en_US |
dc.institutionauthor | Yalçın, Eda Didem | |
dc.language.iso | en | en_US |
dc.publisher | Marmara University | en_US |
dc.relation.ispartof | Clinical and Experimental Health Sciences | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Artifacts | en_US |
dc.subject | Metallic Artifact | en_US |
dc.subject | Streak Artifact | en_US |
dc.subject | Motion Artifact | en_US |
dc.subject | Cone-Beam Computed Tomography | en_US |
dc.title | CBCT artifact evaluation in a single device: Insights and limitations | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication |
Dosyalar
Orijinal paket
1 - 1 / 1
Yükleniyor...
- İsim:
- CBCT artifact evaluation in a single device Insights and limitations.pdf
- Boyut:
- 1.89 MB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Tam Metin / Full Text
Lisans paketi
1 - 1 / 1
Kapalı Erişim
- İsim:
- license.txt
- Boyut:
- 1.44 KB
- Biçim:
- Item-specific license agreed upon to submission
- Açıklama: