CBCT artifact evaluation in a single device: Insights and limitations

dc.authorid0000-0001-8970-7579en_US
dc.authorscopusid57204475611en_US
dc.authorwosidABB-4899-2020en_US
dc.contributor.authorYalçın, Eda Didem
dc.contributor.authorAslan Öztürk, Elif Meltem
dc.date.accessioned2024-07-04T15:12:28Z
dc.date.available2024-07-04T15:12:28Z
dc.date.issued2024en_US
dc.departmentFakülteler, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümü, Ağız, Diş ve Çene Radyolojisi Ana Bilim Dalıen_US
dc.description.abstractObjective: To classify the types of artifacts in cone-beam computed tomography (CBCT) and to evaluate them according to age and gender. Methods: CBCT images of 1500 patients (766 males and 734 females) aged 5-92 (mean age: 40.89 ± 18.82 years) were retrospectively evaluated and the patients were categorized into 4 age groups: under 20 years old, 20-39 ages, 40-59 and over 60 years old. The types of artifacts encountered in CBCT images were classified. The relationship between the artifact types with age and gender were investigated. Chi-square test was applied to analyze the relationships between variables and distribution of parameters. Results: Of the cases, 284 (18.9%) were under the age of 20, 389 (25.9%) were between the ages of 20-39, 554 (36.9%) were between the ages of 40-59 and 273 (18.2%) were over the age of 60. Moire artifact was observed at the highest rate (100%), while motion artifact was determined at the lowest rate (19.5%), and no ring artifact was detected in the analyzed images. Metallic artifact, metallic artifact removal, streak artifact and presence of dark bands were found to be statistically significant in females (p = .002, p = .001, p = .002 and p = .002, respectively). There was no statistically significant correlation between cupping artifact, metallic artifact, metallic artifact removal, streak artifact, dark band and noise, and stitched artifact (p > .05). Conclusion: Both device and patient-based artifacts in CBCT images should be known, as well as the ways to prevent them.en_US
dc.identifier.citationYalçın, E. D., & Aslan Öztürk, E. M. (2024). CBCT artifact evaluation in a single device: Insights and limitations. Clinical and Experimental Health Sciences, 14(2), pp. 349-356. https://doi.org/10.33808/clinexphealthsci.1291106en_US
dc.identifier.doi10.33808/clinexphealthsci.1291106en_US
dc.identifier.endpage356en_US
dc.identifier.issue2en_US
dc.identifier.startpage349en_US
dc.identifier.urihttps://doi.org/10.33808/clinexphealthsci.1291106
dc.identifier.urihttps://hdl.handle.net/20.500.13055/730
dc.identifier.volume14en_US
dc.identifier.wosWOS:001266664000001en_US
dc.identifier.wosqualityQ4en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakTR-Dizinen_US
dc.indekslendigikaynak.otherESCI - Emerging Sources Citation Indexen_US
dc.institutionauthorYalçın, Eda Didem
dc.language.isoenen_US
dc.publisherMarmara Universityen_US
dc.relation.ispartofClinical and Experimental Health Sciencesen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectArtifactsen_US
dc.subjectMetallic Artifacten_US
dc.subjectStreak Artifacten_US
dc.subjectMotion Artifacten_US
dc.subjectCone-Beam Computed Tomographyen_US
dc.titleCBCT artifact evaluation in a single device: Insights and limitationsen_US
dc.typeArticleen_US
dspace.entity.typePublication

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
CBCT artifact evaluation in a single device Insights and limitations.pdf
Boyut:
1.89 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text
Lisans paketi
Listeleniyor 1 - 1 / 1
Kapalı Erişim
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: